Vhp Sterile Pass Box Vaporized Hydrogen Peroxide Chamber Sterilization Rate 6LG
Product Details
| Customization: | Available |
|---|---|
| Optional Accessory: | Drum, Timer Switch, Sterilization Lamp, Floodlight |
| Noise: | 40-60db |
Diamond Member Since 2018
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Year of Establishment
2016-11-30
Number of Employees
9
Find Similar Products
Basic Info.
- Model NO.
- SZ-P
- Surface Treatment
- Electroplating
- Inside Diameter
- 600*600*600mm
- Installation
- Embedded Type
- Operating Principle
- Vhp
- Type
- Self-Cleaning
- Power
- 220V 50/60 Hz
- Color
- Stainless Steel
- Certification
- CE ISO GMP
- Feature
- Easy Cleaning, Corrosion Resistance
- UV Lamp
- 30W*1
- Material
- SUS304#
- Application
- Medical/Health/ Lab/Clean Room
- Interlock
- Mechanical/Electronic
- HEPA Filter
- Efficiency>= 99.999% at 0.3um
- Clean Air Speed
- 0.36~0.54m/S
- Usage
- Dust Removal, Smoke Removal, Sterilization
- Sterilization Cycle Time
- Less Than 120 Min
- Clean Grade
- Class a
- Vhp Residue Removal Efficiency
- <=1ppm
- Transport Package
- Export Wooden Case
- Specification
- 1800*1500*2450mm
- Trademark
- Pharma
- Origin
- China
- HS Code
- 8414609090
- Production Capacity
- 500/Month
Product Description
VHPB series sterilization transfer cabin :
The VHPB series sterilization transfer cabin is a special sterilization equipment that can provide absolute biological
decontamination on the surface of the article when transferring articles between different functions. It is equipped with a dedicated hydrogen peroxide VHP generator, a sterile air supply system, an electromagnetic door interlocking system, a closed system, a residue removal system after sterilization, a dedicated HMI (human machine interface) and a sterilizing medium delivery system. It is widely used for surface sterilization at room temperature in places such as pharmacy, medical treatment, sanitation, biological experiment, etc.
Using VHP technology for sterilization can effectively eliminate bacteria, viruses, and other microorganisms, ensuring that items remain sterile during transmission.
Double door interlocking design
Equipped with a dual door interlock system, ensuring that only one door can be opened at any time to prevent cross contamination.
Durable and sturdy
Made of high-quality stainless steel material, corrosion-resistant, easy to clean, suitable for high cleanliness environments.
User-friendly design
Equipped with transparent observation windows, it is convenient for operators to observe the internal situation in real time. Built in UV lamp and hydrogen peroxide steam generator ensure efficient sterilization.
Easy to operate
By adopting advanced control systems, users can easily operate and monitor the sterilization process in real-time through a touch screen.
decontamination on the surface of the article when transferring articles between different functions. It is equipped with a dedicated hydrogen peroxide VHP generator, a sterile air supply system, an electromagnetic door interlocking system, a closed system, a residue removal system after sterilization, a dedicated HMI (human machine interface) and a sterilizing medium delivery system. It is widely used for surface sterilization at room temperature in places such as pharmacy, medical treatment, sanitation, biological experiment, etc.
Features
Efficient sterilizationUsing VHP technology for sterilization can effectively eliminate bacteria, viruses, and other microorganisms, ensuring that items remain sterile during transmission.
Double door interlocking design
Equipped with a dual door interlock system, ensuring that only one door can be opened at any time to prevent cross contamination.
Durable and sturdy
Made of high-quality stainless steel material, corrosion-resistant, easy to clean, suitable for high cleanliness environments.
User-friendly design
Equipped with transparent observation windows, it is convenient for operators to observe the internal situation in real time. Built in UV lamp and hydrogen peroxide steam generator ensure efficient sterilization.
Easy to operate
By adopting advanced control systems, users can easily operate and monitor the sterilization process in real-time through a touch screen.
Efficient sterilization: The VHP transfer window uses gaseous hydrogen peroxide as a sterilization agent, which has a broad spectrum sterilization effect, and can effectively kill bacteria, viruses, spores and other microorganisms, with a sterilization rate of more than 99.9999%.
Intelligent control: The equipment is equipped with advanced control system, which supports two modes of operation: automatic and manual. Users can set sterilization time, temperature and other parameters according to actual needs to achieve accurate control. At the same time, the system has fault alarm and self-protection functions to ensure the stable operation of the equipment.
Double-door interlock: The VHP transfer window uses a double-door interlock design to ensure that after one door is completely closed and locked, the other door can be opened, effectively preventing cross-contamination of the internal and external environment.
Fast recovery: After sterilization, the residual hydrogen peroxide gas inside the equipment can be quickly discharged through the ventilation system to ensure that the material can be taken out and used in a short time, improving the work efficiency.
Excellent material: The main body of the equipment is made of high-quality stainless steel material, with corrosion resistance, easy to clean and other characteristics, in line with GMP and ISO standards.
| Product Name | VHP Pass Box |
| material quality | Stainless steel SUS 304/SUS 316 |
| Clean Grade | Class A |
| Window material | Tempered glass/acrylic |
| Operation door | Double door interlock |
| Sealing method | Airtight sealing strip |
| surface treatment | Polishing/Drawing |
| control system | PLC control |
| Sterilizing agent | Hydrogen Peroxide (VHP) |
| sterilization time | 30 minutes -120 minutes (adjustable) |
| Sterilization effect | 99.9999% kill rate (6-log) |
| Filtering system | HEPA filter (≥ 99.99% @ 0.3 μ m) |
| Exhaust system | Built in fan |
| sterilization cycle | Automatic loop |
| safety protection | Overpressure protection, leakage detection, automatic alarm system |
| source | 220V/50Hz |
| power | 500W |
| display screen | LCD touch screen |
| Operation interface | Multi language support |
| data record | USB data export |
| Usage environment | Temperature: 10-35 ºC, humidity: ≤ 85% |
| application area | Pharmaceuticals, laboratories, electronics, semiconductors, food, etc |
Instructions for use:
1. Preprocessing
Place the item to be delivered into the VHP Pass Box, ensuring that the surface of the item is dry and clean.
2. Sterilization process
Start the VHP sterilization system and select the sterilization time as needed. The system will automatically generate and release hydrogen peroxide vapor for sterilization.
3. Transmission
After sterilization is completed, the internal system will notify the operator to release the double door interlock. The operator can open the door on one side of the clean area to remove sterilized items.
Maintenance and upkeep:
1. Regular cleaning
After each use, the interior of the VHP Pass Box should be cleaned to prevent residues from affecting the sterilization effect.
2. Check the sealing
Regularly inspect the sealing strip and interlock device of the door to ensure their normal function.
3. Replace consumables
Regularly replace the hydrogen peroxide liquid and UV lamp according to the equipment manual to ensure optimal performance of the equipment.
Notes:
1. Safety protection
During operation and maintenance, protective gloves and masks should be worn to avoid direct contact with hydrogen peroxide.
2. Environmental requirements
The equipment should be installed in a clean, dry, and well ventilated environment, avoiding direct sunlight and high temperature and humidity.
1. Preprocessing
Place the item to be delivered into the VHP Pass Box, ensuring that the surface of the item is dry and clean.
2. Sterilization process
Start the VHP sterilization system and select the sterilization time as needed. The system will automatically generate and release hydrogen peroxide vapor for sterilization.
3. Transmission
After sterilization is completed, the internal system will notify the operator to release the double door interlock. The operator can open the door on one side of the clean area to remove sterilized items.
Maintenance and upkeep:
1. Regular cleaning
After each use, the interior of the VHP Pass Box should be cleaned to prevent residues from affecting the sterilization effect.
2. Check the sealing
Regularly inspect the sealing strip and interlock device of the door to ensure their normal function.
3. Replace consumables
Regularly replace the hydrogen peroxide liquid and UV lamp according to the equipment manual to ensure optimal performance of the equipment.
Notes:
1. Safety protection
During operation and maintenance, protective gloves and masks should be worn to avoid direct contact with hydrogen peroxide.
2. Environmental requirements
The equipment should be installed in a clean, dry, and well ventilated environment, avoiding direct sunlight and high temperature and humidity.