Vhp Isolator with Online Particle Counter and Sterilization System

Product Details
Customization: Available
Certification: GS, CE, ISO9001
Noise: 20-40db
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
9
Year of Establishment
2016-11-30
  • Vhp Isolator with Online Particle Counter and Sterilization System
  • Vhp Isolator with Online Particle Counter and Sterilization System
  • Vhp Isolator with Online Particle Counter and Sterilization System
  • Vhp Isolator with Online Particle Counter and Sterilization System
  • Vhp Isolator with Online Particle Counter and Sterilization System
  • Vhp Isolator with Online Particle Counter and Sterilization System
Find Similar Products

Basic Info.

Model NO.
PH-1200
Control Mode
Touch
Usage
Dust Removal, Smoke Removal, Adding Oxygen, Sterilization
Cleanliness
ISO 5-8
Leakage Rate
Less 0.5%Vol/H(Under 100PA)
The Number of Air Changes
More Than 80t/H
Vaporization Temperature
Less 80 C
Compressed Air
0.3-0.5MPa
Sterilizer
Better Than 30% Food Grade Hydrogen
Vhp Residual Removal Efficiency
Less 1ppm
Control Method
Manual or Automatic
Cabin Material
External Full 304 Stainless Steel, Internal Cavity
Outer Dimension(W*D*H)mm
1600*880*2250
Operating Cabin Size(W*D*H)mm
1195*680*700
Transfer Cabin Size (W*D*H)mm
600*680*700
Power V/Kw
AC220 /3.5
Compressed Air Volume
0.5MPa
Illustrate
Single Double Cabin
Transport Package
Export Package
Specification
Custom request
Trademark
suzhou pharma machinery
Origin
China
HS Code
842489
Production Capacity
20sets/Month

Product Description

Vhp Isolator with Online Particle Counter and Sterilization System
Technical characteristics

Automatic leak detection: inflate the cabin to check if the system remains sealed. If the sealing requirements are met, enter the sterilization process. If the sealing requirements are not met, continue to inflate and seal before leak detection
Cycle until the sealing conditions are met. 
Efficient flash evaporation method: A high-precision constant temperature system ensures zero decomposition of hydrogen peroxide during evaporation, and 100% of hydrogen peroxide forms steam. 
Quick residue removal: The configured hydrogen peroxide decomposer not only can quickly and thoroughly decompose spatial hydrogen peroxide, but also can decompose surface hydrogen peroxide residues.
Sterilization process recording: Automatically detect sterilization concentration and draw sterilization process curves.
Door interlock function: The equipment cannot open the doors during operation. 
Interior surface antibacterial treatment: The interior surface adopts antibacterial treatment, which can achieve sterilization and antibacterial effects, making the interior surface permanently free of microbial habitats.
Compliant with computerized verification software: The system has audit tracking, electronic signature, and data integrity functions.
Bottom mounted features: The bottom mounted transmission cabin has a compact structure, a small footprint, and is easy to operate.
Material External all 304 stainless steel, internal chamber 316L stainless steel
Cleanliness level Class A
Wind speed 0.45m/s ± 20%
Leakage rate ≤ 0.5% VOL/h (below 100pa)
Exhaust volume ≥ 300m ³/ H
Pressure control range 100pa~+100pa
Sterilization efficiency 6lg
VHP residual removal efficiency ≤ 1PPM
Control method Manual or automatic
Noise ≤ 68dB (A)
illumination ≥ 350LUX
 
Model/parameter Overall dimensions
(W*D*H)mm
Operating cabin size
(W*D*H)mm
Transmission compartment size
(W*D*H)mm
Power supply Air supply Explain
TYPE-1200 1600*880*2250 1195*680*700    AC220V

/3.5KW
≥0.6Mpa Single person single cabin
TYPE-1200/BPB600 1600*880*2250 1195*680*700 600*680*700 Single person double cabin
TYPE-1500D/BPB600 2100*1200*2250 1495*1195*700 600*680*700 Single person, double cabin, double sided
TYPE-1800 2200*880*2250 1795*680*700    AC220V

/5.5KW
Double person single cabin
TYPE-1800/BPB600 2200*880*2250 1795*680*700 600*680*700 Double person single cabin
TYPE-1800/PB600 2800*880*2250 1795*680*700 600*680*700 Two person, two cabin
TYPE-1800D/BPB600 2200*1200*2250 1795*1195*700 600*680*700 Double person, double cabin, double sided
 Vhp Isolator with Online Particle Counter and Sterilization System
Vhp Isolator with Online Particle Counter and Sterilization System
Vhp Isolator with Online Particle Counter and Sterilization System
Vhp Isolator with Online Particle Counter and Sterilization System
 
Vhp Isolator with Online Particle Counter and Sterilization System
Vhp Isolator with Online Particle Counter and Sterilization System
Vhp Isolator with Online Particle Counter and Sterilization System
Vhp Isolator with Online Particle Counter and Sterilization System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier